Type: JGS420GS-N, L, Year: 2007, Rated Power: 1416KW, Frequency: 50Hz, Voltage: 400/231V, Current: 2044A, 1500 Rpm, working hrs: 76,000, immediate delivery

1 in stock
Type: JGS420GS-N, L, Year: 2007, Rated Power: 1416KW, Frequency: 50Hz, Voltage: 400/231V,
Type: JGS420GS-N, L, Year: 2007, Rated Power: 1416KW, Frequency: 50Hz, Voltage: 400/231V, Current: 2044A, 1500 Rpm, working hrs: 76,000, immediate delivery

Wartsila Diesel HFO Generator Sets 8R32D
Complete Power House in working order.
WÄRTSILÄ 8R32D HFO Engines (2.9 MW Each) + Full Accessories
🔹 Key Components Include:
✔ 3x WÄRTSILÄ 8R32D Engines (2.9MW each).
✔ Lube Oil Separators (LOPX 705)
✔ Heat Exchangers, Bath Filters, and Exhaust Line with Stack
✔ BAP 021 Control Panel & BAC 021 HT Panel with Cables
✔ HFO Separator & Booster Module
✔ Cooling Towers (250 RT) – 4 Units
✔ HFO Step-Up Transformer (6.6KVA to 11KVA)
✔ Multiple HFO Storage Tanks (Capacity Ranging from 30.81 Ton to 1066.83 Ton)
✔ Power Cables, Pumps, and other essential accessories
✔ 6000V/ 50 Hz/ 337A / 750 Rpm / 3500 Kva /
Chinese Nanjing Captive Coal Fired Power Plant 6.8MW
Design Basis
Design, Engineering, Procurement, Supervision of Installation, and Commission by Nanjing Turbine Power Station Engineering Design Institute (NTCE) of Nanjing China.
1- Boiler system. 2- Steam Turbine system. 3- Generator system. 4- Fuel Conveying system. 5- Lime stone power injection system. 6- Ash & slag handling system. 7- Chemical water treatment system. 8- Water supply & drainage system of power plant. 9- Firefighting system of power plant. 10- Electrical system Control system Ventilation and air conditioning system.
https://youtube.com/shorts/mQQ5BHq6dwQ
Main Technical Index
Total occupied coverage                                                        2.4hm2
Coverage area of each Kw                                                     2m2 /kW
Building coefficient                                                                21%
Site utilization coefficient                                                     38.5 %
Gross Power Generation                                                       6MW
Auxiliary load                                                                         0/78MW
Net Power supply                                                                   5.22 MW
Gross heat rate                                                                        3528.7kcal/kwh
Thermal efficiency for gross power gene                           24.37%
Net heat Rate                                                                          4052.5kcal/kwh
Thermal efficiency for net power supply                           21.22%
Auxiliary load ratio                                                                 13 %
Plant total thermal efficiency (NET)                                      21.2%
Specification of main equipment
Boiler:
Qty                                                                                          1 set
Model                                                                                      UG-35/3.82
Rated output                                                                           35t/h
Main steam temperature                                                        450℃
Main steam pressure                                                               3.82MPa
Feed water temperature                                                          150℃
Flue gas exhaust temperature                                                145℃
Boiler blowdown rate                                                             2%
Fuel                                                                                         Indonesian/South African imported
Design efficiency                                                                    89%
Turbine
Qty                                                                                          1 set
Model                                                                                      N6-3.43 M
Rated power                                                                            6 MW
Rated rotation speed                                                               3000r/min
Rotation direction                                                                   Clockwise direction (by viewing from turbine to generator)
Initial Steam inlet pressure                                                     3.43MPa(a)
Initial Steam inlet temperature                                                435℃
Rated initial steam volume                                                     29t/h
Rated steam rate                                                                      4.672kg/kWh
Rated heat rate                                                                        12406kJ/kWh
Heat recovery system                                                  1 LP Heater +1 Deaerator + 1 HP Heater
Circulating cooling water inlet temperature                           30℃
Rated steam exhaust pressure                                                 0.0084 MPa (a)
Unit vibration value                                                                < 0.03mm
Noise Level                                                                             :< 85db(A)
Governing mode                                                                       DEH (Digital- Electro–Hydraulic)
Generator
Qtya                                                                                        1 set
Model                                                                                      QFW-6.8-2
Rated power                                                                            6.8MW
Rated voltage                                                                          11kV
Rated frequency                                                                      50 HZ
Rated rotation speed                                                               3000r/min
Rated current                                                                          446A
Power factor                                                                           0.8
Efficiency                                                                               97%
Cooling mode                                                                         air-cooled
Rotation direction                                                  Clockwise direction by viewing from the turbine end
level (of stator or rotor)                                                           F level
Overload ability                                                                      10%
Excitation mode                                                                      AC brush less excitation